Skip to search boxSkip to navigationSkip to main content

Artificial intelligence for smart solar energy monitoring: Genetic attention-based hybrid deep–handcrafted fusion for faulty solar panel image classification

  • Abdul Kadir Hamid
    ,
  • Maher Alrahhal
    ,
  • ,
  • Talal Bonny
    ,
  • Yong Chai Tan
    ,
  • Mousa I. Hussein(corresponding author)
*Corresponding author for this work
  • University of Sharjah
    ,
  • UCSI University
    ,
  • SEGi University
    ,
  • United Arab Emirates University
Research Output:
Contribution to journal
Article
Research
Peer-review

Open access

Abstract

With global photovoltaic (PV) capacity exceeding the terawatt scale, timely and accurate fault detection is pivotal to minimizing energy losses and accelerating the transition to net-zero energy systems. In this context, we introduce GA-HyFusionNet—a novel, interpretable, and lightweight hybrid learning framework for solar panel fault classification that combines the strengths of handcrafted and deep features with an optimization-driven fusion strategy. The proposed method begins by extracting low-frequency structural textures via a four-level Discrete Wavelet Transform (DWT), capturing multiscale spatial patterns from grayscale PV imagery. Concurrently, class-specific Bag-of-Visual-Words (BoVW) histograms are generated from Speeded-Up Robust Features (SURF) through modular k-means clustering, producing compact, mid-level descriptors. In parallel, high-level semantic embeddings are obtained from the avg_pool layer of a fine-tuned ResNet50 model. Each feature stream is dimensionally aligned using Principal Component Analysis (PCA), projecting all representations into a unified 300-dimensional latent space. A Genetic Algorithm (GA) then learns optimal attention weights by minimizing the five-fold cross-validation error of a Linear Discriminant Analysis (LDA) classifier, enabling a discriminatively guided and adaptive fusion process. Furthermore, by linking early and accurate detection of dust, cracks, and surface defects to timely cleaning or maintenance of PV modules, GA-HyFusionNet directly minimizes energy yield degradation and reduces downtime, thereby improving operational efficiency and energy sustainability. The framework achieves a peak accuracy of 94.35 % with both LDA and Linear SVM, outperforming deep-only baselines while maintaining low model complexity. Importantly, it requires only 19–21 ms per image at inference and a compact deployment size of ∼87–107 MB, ensuring real-time feasibility on edge devices. By recovering up to 5 % of annual PV energy losses through early and reliable fault diagnosis, GA-HyFusionNet not only reduces the Levelized Cost of Electricity (LCOE) but also advances the practical realization of Sustainable Development Goal 7: Affordable and Clean Energy. Its interpretable architecture, energy-aware design, and real-time feasibility position it as a valuable contribution to next-generation solar diagnostics.

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Article number

107900

Journal (Volume, Issue Number)

Results in Engineering (Volume 28)

Publication milestones

  • Published - 12/2025

Publication status

Published - 12/2025

Publication IDs

  • Scopus: 105022186369

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
1.95

PlumX, opens in new tab

Captures
36
Citation count
9

Sustainable Development Goals

  • SDG 4 - Quality Education
    SDG 4 Quality Education
  • SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  • SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production