Skip to search boxSkip to navigationSkip to main content

A Biosensor for Genetic Modified Soybean DNA Determination via Adsorption of Anthraquinone-2-sulphonic Acid in Reduced Graphene Oxide

  • Raja Zaidatul Akhmar Raja Jamaluddin
    ,
  • Lee Yook Heng(corresponding author)
    ,
  • Ling Ling Tan
    ,
*Corresponding author for this work
  • Universiti Kebangsaan Malaysia
    ,
  • Universiti Malaysia Pahang Al-Sultan Abdullah
Research Output:
Contribution to journal
Article
Research
Peer-review

Abstract

<p>An electrochemical DNA biosensor for DNA determination of genetically modified (GM) soybean (CaMV 35S target genes) was developed utilizing a new detection concept based on the adsoption of anthraquinone-2-sulphonic acid (AQMS) on the reduced graphene oxide nano-particles (rGO) during DNA hybridization events. The aminated DNA probe for CaMV 35S was immobilized onto poly(n-butyl acrylate) film modified with succinimide functional groups [poly(nBA-NAS)] via peptide covalent bond. Nanosheets of rGO were entrapped in the poly(nBA-NAS) film to form a conducting [poly(nBA-NAS)-rGO] film of the DNA biosensor. Besides facilitating the electron transfer reactions, the rGO also functioned as an adsorbent for AQMS. The sensing mechanism of the proposed DNA biosensor involved measuring the oxidation current of the AQMS adsorbed on the electrode surface at −0.50 V using differential pulse voltammetry (DPV) before and after a DNA hybridization event. Under optimum conditions, the DNA biosensor demonstrated a linear proportionality between AQMS oxidation signal and logarithm cDNA concentration from 1.0×10<sup>−15</sup> M to 1.0×10<sup>−8</sup> M target DNA with a detection limit of 6.3×10<sup>−16</sup> M. The electrochemical DNA biosensor possessed good selectivity and a shelf life of about 40 days with relative standard deviation of reproducibility obtained in the range of 3.7–4.6% (n=5). Evaluation of the DNA biosensor using GM soybean DNA extracts showed excellent recovery percentages of 97.2–104.0.</p>

Research Output Information

Output type

Research Output:
Contribution to journal
Article
Research
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 250-258 (9 pages)

Journal (Volume, Issue Number)

Electroanalysis (Volume 30, Issue 2)

Publication milestones

  • Published - 01/02/2018

Publication status

Published - 01/02/2018

ISSN

1040-0397

Publication IDs

  • Scopus: 85041809561

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
0.56

PlumX, opens in new tab

Captures
22
Citation count
14