Effect of membranes on oxygen transfer rate and consumption within a newly developed three-compartment bioartificial liver device: Advanced experimental and theoretical studies
- Ali Hilal-Alnaqbi(corresponding author),
- Abdel Hamid I. Mourad,
- Basem F. Yousef
- United Arab Emirates University,
- Brigham and Women’s Hospital
Research Output:
Contribution to journal
Article
Research
Peer-reviewAbstract
<p>A mathematical model is developed to predict oxygen transfer in the fiber-in-fiber (FIF) bioartificial liver device. The model parameters are taken from the constructed and tested FIF modules. We extended the Krogh cylinder model by including one more zone for oxygen transfer. Cellular oxygen uptake was based on Michaelis-Menten kinetics. The effect of varying a number of important model parameters is investigated, including (1) oxygen partial pressure at the inlet, (2) the hydraulic permeability of compartment B (cell region), (3) the hydraulic permeability of the inner membrane, and (4) the oxygen diffusivity of the outer membrane. The mathematical model is validated by comparing its output against the experimentally acquired values of an oxygen transfer rate and the hydrostatic pressure drop. Three governing simultaneous linear differential equations are derived to predict and validate the experimental measurements, e.g., the flow rate and the hydrostatic pressure drop. The model output simulated the experimental measurements to a high degree of accuracy. The model predictions show that the cells in the annulus can be oxygenated well even at high cell density or at a low level of gas phase P<sub>G</sub> if the value of the oxygen diffusion coefficient D<sub>m</sub> is 16 × 10<sup>-5</sup>. The mathematical model also shows that the performance of the FIF improves by increasing the permeability of polypropylene membrane (inner fiber). Moreover, the model predicted that 60% of plasma has access to the cells in the annulus within the first 10% of the FIF bioreactor axial length for a specific polypropylene membrane permeability and can reach 95% within the first 30% of its axial length.</p>
Research Output Information
Output type
Research Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 304-315 (12 pages)Journal (Volume, Issue Number)
Biotechnology and Applied Biochemistry (Volume 61, Issue 3)Publication milestones
- Published - 2014
Publication status
Published - 2014
ISSN
0885-4513Publication IDs
- Scopus: 84903318900
- PubMed: 24164246
Documents and links
Publication metrics
Metrics
SciVal
FWCI
0.11
PlumX, opens in new tab
Captures
7
Citation count
1